eds and efd explosionproof cl i div 1 2 groups b c

2A EDS and EFD Enclosures Cl. I, Div. 1 & 2, Groups B*, C

2A EDS and EFD Enclosures with General Use Snap Switches Front Operated Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations EDS Enclosed Snap Switch Applications:EDS and EFD enclosures are installed in a

2A EDS and EFD Enclosures Explosionproof Dust

2A EDS and EFD Enclosures with General Use Snap Switches Front Operated Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG, 12 Explosionproof Dust-Ignitionproof Raintight Wet Locations EDS Enclosed Snap Switch Applications:EDS and EFD enclosures are installed in a 4C DSD Cover and Device Cl. I. Div. 1&2, Groups B*, C, D Cl. I, Div. 1&2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations DSD951 DSD925 DSD947-J1-J1 DSD958 DSD957 DSD961-J1 For use with EDSCM modular control device bodies listed on catalog page 392 & EFS/EDS back boxes listed on catalog page 397.

5C-6 EPS Factory Sealed Cl. I, Div. 1 & 2, Groups B.C

Dimensions Pg. 5C-2 Cl. I, Div. 1 & 2, Groups B.C.D Cl. II, Div. 1, Groups E.F.G Cl. II, Div. 2, Groups F,G Cl. Ill NEMA3,7BCD,9EFG Explosionproof Dust-lgnitionproof Raintight Wet Locations Pilot lights listed below are factory sealed and do not require external seals. Lamps * are 6 watt, type S6, candelabra base for use on 110-125 volt circuits. 5C-8 EDS Factory Sealed CM, Div. 1 & 2, Groups B*,C Duty, Dimensions Pg. 5C-2 CM, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl.ll, Div. 2, Groups F,G Cl. Ill NEMA3,7B*CD,9EFG Explosionproof Dust-lgnitionproof Raintight Wet Locations Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify

EDS / EFS Series 4C Cl. I. Div. 1 & 2, Groups B*, C, D

EDS / EFS Series 4C Cl. I. Div. 1 & 2, Groups B*, C, DExplosionproof Control Stations. crouse-hinds US:1-866-764-5454 CAN:1-800-265-0502 Copyright©2016 Eaton. 4C. EDS / EFS Series 4C Control Stations. DSD Cover and Device Sub-assemblies. Cl. I. Div. 1 & 2, Groups B*, C, D Cl. EDS / EFS Series Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations EDSC2162 EDS2696 Ordering Information - Single Gang Normal Pos. 1 Circuit Universal 2 Circuits Universal 2 Circuits Marking Specify Specify START-STOP unless otherwise specified Diagram

EDS / EFS Series Cl. I, Div. 1 & 2, Groups B*, C, D

EDS / EFS Series Cl. I, Div. 1 & 2, Groups B*, C, D Explosionproof 4C Control Stations Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof Cl. II, Div. 2, Groups F, G Raintight Fully Assembled EFS and Cl. III Wet Locations EDS Factory Sealed Devices NEMA 3, 7B*CD, 9EFG. crouse-hinds US:1-866-764-5454 CAN:1-800-265-0502 Copyright©2016 Eaton. EDS / EFS Series Cl. I, Div. 1 & 2, Groups B*, C, D EDS Factory Sealed Devices Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from

EDS / EFS Series Cl. I. Div. 1 & 2, Groups B*, C, D

Cl. I. Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations DSD951 DSD925 DSD947-J1-J1 DSD958 DSD957 DSD961-J1 For use with EDSCM modular control device bodies see page 0000 & EFS/EDS back boxes. Ordering Information EDS / EFS Series Cl. I. Div. 1 & 2, Groups B*, C, D Cl. I. Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations For use with EDSCM modular control device bodies see page 513 and EDS/EDSC back boxes. Features: Large machine screws for fastening covers to bodies

EDS / EFS Series Control StationsCl. I, Div. 1 & 2, Groups

EDS / EFS Series Control Stations Fully Assembled EDS Factory Sealed General Use Snap Switches Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations EDSC2129 EDS2229 Ordering Information - General Use Snap Switch Front Operated EDS Factory Sealed Cl. I, Div. 1 & 2, Groups B*,C,D RB Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations Application:Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used:

EDS Factory Sealed Cl. I, Div. 1 & 2, Groups B*,C,D RB

Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,7B*CD,9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. EDS Factory Sealed General Use Cl. I, Div. 1 & 2, Groups B Dimensions Pg. 5C-2 Cl. I, Div. 1 & 2, Groups B' Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. Ill NEMA3,7B*CD,9EFG,C,D Explosionproof Dust-lgnitionproof Raintight Wet Locations 5C-9 EDSC2129 EDS2229 General Use Snap Switch - Front Operated Hub Size % 3/4 3/4 3/4 1 1 1 1 Stylet 1-pole 2-pole 3-way 4-way 1-pole 2-pole 3-way 4-way

EDS Factory Sealed Push Cl. I, Div. 1 & 2, Groups B*,C,D

Cl. II, Div. 1, Groups E.F.G Cl. II, Div. 2, Groups F,G Cl. Ill NEMA3,7B*CD,9EFG Explosionproof Dust-lgnitionproof Raintight Wet Locations 5C-3 EDSC2162 Single Gang Normal Pos. 1 Circuit Universal Marking t Specify 2 Circuits Universal Specify 2 Circuits 1 Open-A 1 Closed-B START-STOP unless otherwise specified EDS2696 Two Gang Normal Pos. 1 EFD/EFDB and EDS Series Factory Sealed Control StationsClass I, Division 1 and 2, Groups B , C, D Class II, Division 1 and 2, Groups E, F, G Class III NEMA 3, 7CD, 9EFG EFD/EFDB and EDS Series Factory Sealed Control Stations Explosionproof, Dust-Ignitionproof Devices Device Description Available in 1-G, 2-G, Tandem Available in 3-Device Suffix One Pilot Light (Red Standard) Y J1 Two Pilot Lights Y J2

ENR Dead Front Interlocked Cl. I, Div. 1 & 2, Groups B,C

Ark Gard 2; Factory Sealed Cl. I, Div. 1 & 2, Groups B,C,D Cl. II, Div. 1 & 2, Groups F,G Cl. III NEMA 3,7BCD,9FG,12 Explosionproof Dust-Ignitionproof Raintight Wet Locations Application:ENR receptacles and ENP plugs are used:with portable electrical equipment such as compressors, tools, lighting systems, and similar devices ENR Dead Front Interlocked Cl. I, Div. 1 & 2, Groups B,C Ark Gard® 2; Factory Sealed Cl. I, Div. 1 & 2, Groups B,C,D Cl. II, Div. 1 & 2, Groups F,G Cl. III NEMA 3,7BCD,9FG,12 Explosionproof Dust-Ignitionproof Raintight Wet Locations Application:ENR receptacles and ENP plugs are used:with portable electrical equipment such as compressors, tools, lighting systems, and similar devices

EDS / EFS Series Cl. I, Div. 1 & 2, Groups B*, C, D

EDS Factory Sealed Devices Cl. I, Div. 1 & 2, Groups B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 7B*CD, 9EFG Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment